Sunny Tripower
Dispositivos compatibles
| Device Type | Variants | Modbus TCP (Ethernet) | Curtailment | Minimum device firmware version |
|---|---|---|---|---|
| Sunny Tripower | STP 3.0 | ✅ | ✅ | 4.03.07.R |
| STP 4.0 | ||||
| STP 5.0 | ||||
| STP 6.0 | ||||
| STP 8.0 | ||||
| STP 10.0 | ||||
| Sunny Tripower X | STP X12 | 03.12.15.R | ||
| STP X15 | ||||
| STP X20 | ||||
| STP X25 | ||||
| Sunny Tripower TL | STP 8000TL-10 | 02.65.02.R | ||
| STP 10000TL-10 | ||||
| STP 12000TL-10 | ||||
| STP 15000TL-10 | ||||
| STP 17000TL-10 | ||||
| STP 5000TL-20 | ||||
| STP 6000TL-20 | ||||
| STP 7000TL-20 | ||||
| STP 8000TL-20 | ||||
| STP 9000TL-20 | ||||
| STP 15000TL-30 | ||||
| STP 17000TL-30 | ||||
| STP 20000TL-30 | ||||
| STP 25000TL-30 | ||||
| Sunny Tripower TLEE | STP 10000TLEE-10 | 02.50.87.R | ||
| STP 15000TLEE-10 | ||||
| STP 20000TLEE-10 | ||||
| Sunny Tripower Core 1 | STP 50-40 | 4.01.05.R | ||
| STP 50-41 | ||||
| Sunny Tripower Core 2 | STP 110-60 | 1.01.04.R |
Cableado
Para un cableado ethernet correcto: Siga las pautas para el cableado ethernet.
Configuración
- Conéctese con su computadora a la misma red LAN que el SMA Sunny Tripower.
- En su navegador web, acceda a la dirección IP del dispositivo.
- Inicie sesión como "Instalador."

- Vaya a la pestaña de parámetros del dispositivo.

- Haga clic en "Editar parámetros."
- Abra el menú desplegable "Comunicación externa" → "Modbus" → "Servidor TCP."
- Configure "Activado" en "Sí" y "Puerto" en "502".
- En la parte superior de la página, haga clic en "Guardar todo."